+86 182 2109 4035
support@shanghai-cm.com

Brackish Water RO Membrane

BW Series Industrial Brackish Water RO Membrane for Groundwater & Industrial Water Desalination Projects.

  • 99.7% high salt rejection for steady outlet water quality
  • Hydrophilic membrane resists dirt from organics and colloids easily
  • Works well with brackish water of 2000~10000ppm salt content
Brackish Water RO Membrane

BW Series Brackish Water RO Membrane

High desalination brackish water reverse osmosis membrane elements

BW8040 RO Membrane

RO Membrane BW8040

  • Effective Membrane Area: 400 ft² /37 m²
  • Flux: 11000 GPD(41.6m³/d)
  • Salt Rejection: 99.7%
View Details
BW8440 RO Membrane

RO Membrane BW8440

  • Effective Membrane Area: 440 ft² /41 m²
  • Flux: 12000 GPD(45m³/d)
  • Salt Rejection: 99.7%
View Details
BW4040 RO Membrane

RO Membrane BW4040

  • Effective Membrane Area: 78 ft² /7.2 m²
  • Flux: 2500 GPD(9.5m³/d)
  • Salt Rejection: 99.7%
View Details
BW2540 RO Membrane

RO Membrane BW2540

  • Effective Membrane Area: 30 ft² /2.8 m²
  • Flux: 1800 GPD(6.8m³/d)
  • Salt Rejection: 99.2%
View Details
BW2521 RO Membrane

RO Membrane BW2521

  • Effective Membrane Area: 13 ft² /1.2 m²
  • Flux: 370 GPD(1.4m³/d)
  • Salt Rejection: 99.2%
View Details
BW4021 RO Membrane

RO Membrane BW4021

  • Effective Membrane Area: 36 ft² /3.3 m²
  • Flux: 1000 GPD(3.8m³/d)
  • Salt Rejection: 99.5%
View Details

Brackish Water RO Membrane Specifications

Technical parameters for industrial reverse osmosis membrane models

Model Effective Membrane Area
ft²(m²)
Average Yield
GPD(m³/d)
Salt Rejection
(%)
Recovery Rate
(%)
BW-2521 13 (1.2) 370 (1.4) 99.2 8
BW-2540 30 (2.8) 800 (3.0) 99.2 15
BW-4021 36 (3.3) 1000 (3.4) 99.5 15
BW-4040 78 (7.2) 2500 (9.5) 99.7 15
BW-8040 400 (37) 11000 (41) 99.7 15
BW-8440 440 (41) 12100 (45) 99.7 15

Note: All specifications are measured under standard test conditions (25°C, 2000 ppm NaCl, 15% recovery for 4040/8040/8440 models). Actual performance may vary based on feed water quality and operating conditions.

Stable Performance for Critical Applications

When treating brackish water, unstable membrane performance can lead to:

  • Increased energy consumption
  • Frequent CIP cleaning
  • Unstable permeate conductivity
  • Reduced recovery rate
  • Unexpected replacement costs

Our BWRO Solution Delivers:

  • Stable ≥99% salt rejection
  • Optimized operating pressure
  • Reduced fouling tendency
  • Extended membrane lifespan
  • Reliable compatibility with standard 4040 & 8040 vessels

Designed for industrial RO systems operating continuously in municipal, power plant, and manufacturing environments.

Why Engineering Companies Choose Our BWRO Membranes

Balanced Flux & Rejection Design

High flux alone increases fouling risk. High rejection alone increases pump load.

Our membranes maintain:

  • Stable permeate conductivity
  • Controlled permeate flow
  • Lower differential pressure growth

Reduces cleaning frequency & operating cost.

Lower Operating Pressure

Compared to conventional medium-pressure membranes:

  • Reduced pump power consumption
  • Lower mechanical stress
  • Improved long-term stability

Save energy over 3–5 years operating cycle.

Enhanced Anti-Fouling Surface

Hydrophilic surface modification improves:

  • Organic fouling resistance
  • Biofouling control
  • Easy cleanability during CIP

Stable output under industrial conditions.

Application Scenarios

Our Brackish Water RO Membranes are widely applied in:

Groundwater Desalination

Municipal and industrial groundwater treatment

Municipal Water Treatment

Large-scale water treatment plants

Boiler Feed Water

Preparation for power plants and industrial boilers

Textile Industry

Process water systems and wastewater treatment

Electronics Manufacturing

High-purity water for semiconductor production

Industrial Wastewater Reuse

After proper pretreatment for water recycling

If your feed water TDS is below 10,000 ppm, BWRO membranes are typically the most cost-efficient solution.

Replacement & OEM Capability

Our membranes are fully compatible with:

  • Standard 4040 & 8040 pressure vessels
  • International industrial RO system configurations

Available Services:

  • OEM private label manufacturing
  • Bulk project supply
  • Technical data support
  • Stable long-term export supply
  • Engineering consultation

For distributors and project contractors, we ensure consistent batch quality and reliable lead times.

Technical Operating Limits

To ensure optimal lifespan

Maximum Operating Pressure

600 psi

Max Temperature

45°C

pH Range (continuous)

2-11

SDI

≤ 5

Free Chlorine

< 0.1 ppm

Correct pretreatment design is essential for long-term stability.

How to Select the Right BWRO Membrane

We Require:

  1. 1 Feed water analysis report
  2. 2 Required permeate capacity (m³/h)
  3. 3 Target recovery rate
  4. 4 Application type

Our Engineering Team Will:

  • Evaluate scaling risk
  • Estimate expected permeate conductivity
  • Recommend optimal membrane configuration
  • Provide project quotation

Response time: within 24 hours.

Cost Optimization for EPC & Integrators

For engineering companies and system integrators

Competitive Pricing

Wholesale pricing for bulk orders

Stable Capacity

Reliable production capacity

Flexible Cooperation

Project cooperation models

Custom Branding

Custom packaging & branding

We support municipal engineering firms, industrial EPC contractors, and water treatment integrators globally.

Frequently Asked Questions

Technical guidance for brackish water RO membrane selection and operation

Still have technical questions about membrane selection or replacement?

Send us your water analysis report -- our engineers will assist you directly.

What TDS range is suitable for brackish water RO membranes?

Brackish water RO membranes are typically designed for feed water with TDS between 2,000-10,000 ppm. If salinity exceeds this range, a seawater RO membrane is usually recommended due to higher operating pressure requirements.

What is the difference between BWRO and SWRO membranes?

The main differences are:

  • Operating pressure
  • Salt rejection structure
  • Structural strength
  • Energy consumption

BWRO membranes operate at lower pressure and are optimized for medium salinity water, while SWRO membranes are designed for high-salinity seawater applications.

What is the typical salt rejection rate?

Under standard test conditions (2,000 ppm NaCl, 25°C, 15% recovery):

  • 4040 BWRO membrane: ≥ 99%
  • 8040 BWRO membrane: ≥ 99.5%

Actual rejection depends on feed water composition and system design.

How long does a brackish water RO membrane last?

With proper pretreatment (SDI ≤ 5, turbidity < 1 NTU), typical service life is 3-5 years under industrial operation.

Factors affecting lifespan include:

  • Scaling tendency
  • Organic fouling
  • Cleaning frequency
  • Operating pressure
Can your membranes replace international brand elements directly?

Yes.

Our 4040 and 8040 brackish water RO membranes are dimensionally compatible with standard industrial pressure vessels and can be used as direct replacements in most existing systems without structural modification.

We recommend verifying operating pressure and flow design before replacement.

What pretreatment is required before BWRO membranes?

To protect membrane performance, the feed water should meet:

  • SDI ≤ 5
  • Turbidity < 1 NTU
  • No free chlorine (≤ 0.1 ppm)
  • Proper hardness control to prevent scaling

Typical pretreatment includes:

  • Multimedia filtration
  • Activated carbon filtration
  • Softening or antiscalant dosing
  • Cartridge filtration (5 micron)
How often should membranes be cleaned (CIP)?

Cleaning is recommended when:

  • Permeate flow declines by 10-15%
  • Salt rejection drops by 10%
  • Pressure differential increases by 15%

Actual cleaning frequency depends on feed water quality and system recovery rate.

What is the recommended recovery rate for brackish water systems?

Typical system recovery:

  • 60-75% for groundwater applications
  • Lower recovery may be required for high scaling risk water

Recovery design should be based on full water analysis and scaling calculation.

Do you provide membrane selection support for projects?

Yes.

If you provide:

  • Feed water analysis
  • Target permeate capacity
  • Application type
  • Required recovery rate

Our engineering team will recommend suitable membrane models and provide technical support within 24 hours.

Do you support OEM or private labeling?

Yes.

We provide:

  • OEM branding
  • Custom packaging
  • Bulk project supply
  • Stable export logistics
  • Long-term cooperation for distributors and EPC contractors

All membranes undergo individual wet testing before shipment.

Request Technical Datasheet or Project Quotation

If you are currently:

✓ Designing a new RO system

✓ Replacing existing BWRO membranes

✓ Quoting a municipal or industrial project

✓ Looking for a reliable OEM membrane supplier

Contact us with your water analysis.

Our engineers will provide:

  • Model recommendation
  • Technical parameters
  • Performance expectations
  • Bulk pricing proposal

We will help you select the right brackish water RO membrane for stable long-term operation.

CONTACT SHANGHAI CM

We'd love to hear from you. Please fill out the form or contact us directly using the information below.

Kaimi He
+86 18221094035
support@shanghai-cm.com
Building 9, No. 1188 Jiangyue Road, Minhang District, Shanghai

Get in Touch